Lenovo Fan Cooling 1U SR630 SR655 SR635 1U FAN MOD 4F17A12358
Part Number: 4F17A12358
Manufacturer: Lenovo
Product Name: ThinkSystem 1U Fan Module
Category: Server Cooling / Fan Option Kit
Form Factor: 1U server fan module
The Lenovo 4F17A12358 is a hot-swap system cooling fan module designed for Lenovo ThinkSystem 1U rack servers. It provides forced-air cooling for CPU, memory, and internal components, ensuring thermal stability in high-density enterprise environments.
This module is used in servers such as:
ThinkSystem SR630
ThinkSystem SR635
ThinkSystem SR655
It is part of Lenovo’s modular cooling architecture, allowing redundant, field-replaceable airflow management in mission-critical systems.
Product Type: Cooling fan module
Server Form Factor: 1U rackmount
Application: Enterprise server thermal management
Hot-Swap: Yes (field replaceable, no shutdown required — typical for ThinkSystem fans)
Module Type: Plug-in fan cartridge
Mounting: Internal chassis slot (fan bay)
Cooling Method: High-speed axial fan(s) in modular housing
Airflow Direction: Front-to-back (standard data center airflow)
(Exact values not always published for FRU parts; based on platform characteristics)
Voltage: 12V DC (server rail standard)
Control: PWM-controlled variable speed
Connector: Board-mounted blind-mate interface
Cooling Role:
CPU thermal dissipation
DIMM / memory cooling
PCIe and storage airflow
Redundancy Support: Yes (N+1 fan redundancy depending on configuration)
Speed Control: System-managed via Lenovo XClarity / firmware
Primary Systems:
Lenovo ThinkSystem SR635 (7Y99 platform)
Also used across similar 1U platforms:
SR630 / SR655 (shared thermal design family)
Maintains safe operating temperatures for:
CPUs (high TDP Xeon / EPYC)
Memory modules
Storage controllers
Enables high-density compute workloads without thermal throttling
Fully integrated with:
Lenovo XClarity Controller (XCC)
BIOS thermal profiles
Supports:
Dynamic fan curves
Failure detection & alerting
Automatic speed ramp under load
Hot-pluggable design minimizes downtime
Designed for tool-less replacement
Identified as FRU (Field Replaceable Unit)
High-RPM dual-rotor or single-rotor axial fan design
Optimized for:
Static pressure (important for dense server chassis)
Directed airflow channels
Works with air shrouds to guide airflow over CPUs and DIMMs
Used in data center / enterprise IT environments
Critical for:
Virtualization clusters
Storage servers
High-performance compute nodes
Failure or removal typically results in:
Immediate fan redundancy alert
Possible thermal throttling or shutdown if insufficient cooling
This part is not just a “fan”—it’s a system-level thermal component tied into:
Firmware control loops
Redundancy schemes
Data center airflow standards
From a sourcing standpoint (relevant to your work), it falls under:
Server FRU / spare parts
High replacement frequency due to wear (moving component)